Digital radiography flat panel detector has the advantages of small radiation, strong penetrating power and fast imaging speed compared with conventional ray detection. Imaging systems replaces film imaging, saving high cost of consumables.
At the same time, darkroom washing process is not required, the adverse effects of chemical agents on the human body are eliminated.
Parameter
Pixel Pitch | 120μm | |
A/D Resolution | 16bit | |
X-ray Sensing Material | Csi | |
Dynamic Range | 12000:1 | |
Line Pair Resolution | 4.16lp/mm | |
Imaging Area | Full view | 307mmx244mm(10"x12') |
ROI | 184mmx184mm(7.3"x7.3") | |
Pixel Matrix | Full view matrix | 2560x2048 |
ROI View matrix(1x1) | 1536x1536 | |
ROI View matrix (2x2,binning) | 768x768 | |
Read out Rate | Full view | 2-3s |
ROI View(1x1) | 4 Fps | |
ROI view(2x2,binning) | 15 Fps | |
Energy Interval | 20-320kv (Internal shielding, tungsten) | |
Dimensions | 344mm*286mm*20mm | |
Weight | About 8KG | |
Data Interface | GigE |
Advantage:
The DR detection speed is much higher than the CR detection speed, and the impact data can be collected in only a few tens of seconds.
Images can be acquired automatically, including image selection, correction, dynamic range and grayscale reconstruction, and the process of output
matching is done in the computer's fully automated process. Image magnified and the defect can be quantified and graded using a computer-assisted assessment. Computer-assisted assessment can improve the speed and accuracy of the assessment.
Imaged relative to film, which saves on the cost of consumable film and eliminates the need for film processing.
Computer Digital Image Processing and Enhancement Software System
Image enhancement and storage system integration the most practical processing and filtering function ,designed for X-ray real-time imaging system, can be processed image sensitivity increased by 0.6% - 0.8% on average, with the aid of high-speed ethernet front-end ports, can get static images and dynamic image, and saved as a 8/16 bit image formats, and can be directly record on the DVD for permanent preservation, facilitate the detecting data archiving and review, save testing cost and file serve.
Hierarchical management: Operators: All test parameters are preset, and operators can start the operation with one click.
Manager: The detection parameters can be set and adjusted, the image can be advanced evaluation and processing.
Raylion image enhancement function makes the image clearer -- filtering and enhancement can be performed under both dynamic and static conditions
Real-time and Post-capture Image Processing Functions:
Real-Time Observation | Capture Image | |
Image filtering enhancement | Yes (1 ) | Yes(5) Image capture can automatically attach selected filter processing |
ROI Quick Gray Level Adjustment | Yes | Yes |
Stepless Zoom | Yes | Yes |
Dimensional Measurement | Yes | Yes |
Size Marking | Yes | |
Integral Noise Reduction | 2/4/8 | 2/4/8/16/32/64/128/256 |
Negative Film | Yes | Yes |
Pseudo-Color
| Yes | Yes |
Video | Yes | |
Image Information Marking | Yes (Video recording can record the marking information simultaneously) | Yes |
Storage Format | AVI | bmp / png / jpg / tiff(8bit/16bit) / RAW / his / dcm |
Image to Flip | Yes | Yes |
Sofeware: ZXVISPRO Distance: 300mm (Block to x-ray source) IQI: ASTM1A 1B & EN 6 10 Flat Panel Calibration:60KV&1mA | ||||
FPD | Varian 3025
| Varian 3025
| China ZXP2530
| China ZXP2530
|
X-ray Source |
Model:ZY-220HP |
Model:ZY-320HP |
Model:ZY-220HP |
Model:ZY-320HP |
18mm Block
| 220KV 3mA result PIC06 | 200KV 3mA result PIC09 | 200KV 3mA result PIC12 | 170kv 3mA result PIC11 |
210kv 3mA result PIC07 | ||||
220KV 3mA result PIC13 | 200KV 3mA result PIC14 | |||
200kv 3mA result PIC08 | ||||
25mm Block
| 220KV 3mA result PIC05 Failed | 260KV 3mA result PIC04 | 260kv 3mA result PIC15 | |
280KV 3mA result PIC03 | ||||
30mm Block
| 290KV 3mA result PIC01 | |||
300KV 3mA result PIC02 |